{"product_id":"bus-cable-3-wire-de-corriente-alterna-apsystems-12awg-para-ds3d-ds3-h-y-yc600b","title":"Cable Bus AC 3 Hilos 12 AWG Microinversores DS3D DS3-H YC600B APSystems APS-BusCable-DS3\/YC600-12AWG","description":"\u003cdiv class=\"mt-desc\"\u003e\n\u003cstyle\u003e.mt-desc{color:#1a1a1a;max-width:860px;margin:0 auto;line-height:1.65}.mt-desc h1{font-size:26px;font-weight:800;margin-bottom:6px}.mt-desc .subtitulo{font-size:15px;color:#555;margin-bottom:24px}.mt-desc h2{font-size:19px;font-weight:700;border-left:4px solid #cc1f1f;padding-left:10px;margin:30px 0 12px}.mt-desc p{margin:0 0 14px;font-size:15px}.mt-desc ul{margin:0 0 14px 18px;padding:0}.mt-desc li{margin-bottom:7px;font-size:15px}.mt-desc table{width:100%;border-collapse:collapse;margin:12px 0 20px;font-size:14px}.mt-desc th{background:#f2f2f2;padding:10px 12px;text-align:left;font-weight:700;border-bottom:2px solid #ddd}.mt-desc td{padding:9px 12px;border-bottom:1px solid #eee}.mt-desc td:first-child{font-weight:600;width:42%}.mt-desc .faq-item{border:1px solid #e8e8e8;border-radius:8px;margin:10px 0;overflow:hidden}.mt-desc .faq-item summary{cursor:pointer;padding:13px 16px;font-weight:700;font-size:15px;list-style:none;background:#fafafa}.mt-desc .faq-item .faq-body{padding:12px 16px 14px;font-size:14px;border-top:1px solid #eee}.mt-desc .badge-row{display:flex;flex-wrap:wrap;gap:10px;margin:12px 0 20px}.mt-desc .badge{background:#f0f4ff;color:#1a3cc8;border:1px solid #c5d0f5;border-radius:20px;padding:5px 14px;font-size:13px;font-weight:600}.mt-desc .badge.green{background:#f0fff4;color:#1a7a3c;border-color:#b2dfca}.mt-desc .badge.red{background:#fff0f0;color:#b00020;border-color:#f5c5c5}.mt-desc .badge.gray{background:#f5f5f5;color:#444;border-color:#ddd}.mt-desc .badge.yellow{background:#fffbe6;color:#7a5c00;border-color:#f0d870}.mt-desc .apps-grid{display:grid;grid-template-columns:1fr 1fr;gap:10px;margin:12px 0}.mt-desc .app-card{background:#f8f8f8;border-radius:8px;padding:12px 14px;font-size:14px;border-left:3px solid #cc1f1f}.mt-desc .app-card strong{display:block;margin-bottom:4px}.mt-desc .contenido-grid{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0}.mt-desc .contenido-chip{background:#fff0f0;border:1px solid #f5c5c5;border-radius:6px;padding:6px 14px;font-size:14px;color:#b00020;font-weight:600}\u003c\/style\u003e\n\u003ch1\u003eCable Bus 3 Hilos Corriente Alterna 12 AWG Microinversores DS3D DS3-H YC600B APSystems APS-BusCable-DS3\/YC600-12AWG\u003c\/h1\u003e\n\u003cp class=\"subtitulo\"\u003eModelo APS-BusCable-DS3\/YC600-12AWG | Marca APSystems\u003c\/p\u003e\n\u003cdiv class=\"badge-row\"\u003e\n\u003cspan class=\"badge green\"\u003eCable AC 3 Hilos\u003c\/span\u003e\u003cspan class=\"badge\"\u003eCalibre 12 AWG\u003c\/span\u003e\u003cspan class=\"badge yellow\"\u003eCompatible DS3D\u003c\/span\u003e\u003cspan class=\"badge yellow\"\u003eCompatible DS3-H\u003c\/span\u003e\u003cspan class=\"badge yellow\"\u003eCompatible YC600B\u003c\/span\u003e\u003cspan class=\"badge\"\u003eCertificado Solar\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp\u003eEl Cable Bus APS-BusCable-DS3\/YC600-12AWG es un cable de corriente alterna trifásico calibre 12 AWG especialmente diseñado para interconectar microinversores APSystems modelos DS3D, DS3-H y YC600B, con capacidad de hasta 20A continuos y certificación SOOW para instalaciones fotovoltaicas intemperie según NEC 690. Este cable bus permite la conexión en cadena (daisy-chain) de múltiples microinversores en sistemas solares residenciales y comerciales, reduciendo tiempo de instalación y asegurando cumplimiento normativo con conductores de cobre suave clase B calibre 12 AWG para fase, neutro y tierra.\u003c\/p\u003e\n\u003cp\u003eFabricado con aislamiento de neopreno resistente a rayos UV, aceites y temperaturas extremas (-40°C a +90°C), el cable bus APSystems garantiza operación confiable en condiciones exteriores durante toda la vida útil del sistema fotovoltaico. Su calibre 12 AWG (3.31 mm²) cumple con los requisitos de caída de voltaje para ramales de hasta 12 microinversores en configuraciones típicas, optimizando la eficiencia energética del sistema solar. Compatible con conectores de bloqueo rápido APSystems para instalación sin herramientas, este cable reduce costos de mano de obra y minimiza errores de conexión en campo.\u003c\/p\u003e\n\u003cp\u003eEste cable de interconexión AC es componente esencial en sistemas de microinversores APSystems de última generación, permitiendo arquitectura modular donde cada panel solar opera de forma independiente con su propio microinversor, maximizando la producción energética en instalaciones con sombreado parcial o techos con múltiples orientaciones. El cable bus trifásico transporta la energía convertida de DC a AC desde los microinversores hasta el punto de interconexión con la red eléctrica o el centro de carga.\u003c\/p\u003e\n\u003ch2\u003eBeneficios Principales\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCable AC bus certificado SOOW para instalaciones solares exteriores según NEC 690 y UL 4703, garantizando seguridad eléctrica y cumplimiento normativo en inspecciones municipales\u003c\/li\u003e\n\u003cli\u003eCalibre 12 AWG optimizado para transportar 20A continuos con mínima caída de voltaje en ramales de hasta 12 microinversores DS3D\/DS3-H\/YC600B\u003c\/li\u003e\n\u003cli\u003eConstrucción trifásica (3 conductores) con fase, neutro y tierra de cobre suave clase B, asegurando conexión a tierra segura y protección contra fallas\u003c\/li\u003e\n\u003cli\u003eAislamiento de neopreno SOOW resistente a rayos UV, ozono, aceites, abrasión y temperaturas de -40°C a +90°C, ideal para instalaciones en azoteas y exteriores\u003c\/li\u003e\n\u003cli\u003eCompatible con sistema de conectores de bloqueo rápido APSystems que eliminan necesidad de herramientas, reduciendo tiempo de instalación hasta 40% versus cableado tradicional\u003c\/li\u003e\n\u003cli\u003eDiseño daisy-chain (conexión en cadena) que simplifica arquitectura del sistema solar y reduce número de conductores necesarios versus cableado punto a punto\u003c\/li\u003e\n\u003cli\u003eFlexibilidad mecánica que facilita ruteo en techos con obstáculos, penetraciones y esquinas, adaptándose a geometrías complejas sin comprometer radio de curvatura\u003c\/li\u003e\n\u003cli\u003eCódigo de colores UL estándar (negro-fase, blanco-neutro, verde-tierra) que acelera identificación durante instalación, mantenimiento y resolución de problemas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEspecificaciones Técnicas\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCaracterística\u003c\/th\u003e\n\u003cth\u003eEspecificación\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo de Cable\u003c\/td\u003e\n\u003ctd\u003eBus Cable AC 3 Hilos (Fase, Neutro, Tierra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibre\u003c\/td\u003e\n\u003ctd\u003e12 AWG (3.31 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial Conductor\u003c\/td\u003e\n\u003ctd\u003eCobre Suave Clase B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNúmero de Conductores\u003c\/td\u003e\n\u003ctd\u003e3 (3-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAislamiento\u003c\/td\u003e\n\u003ctd\u003eNeopreno SOOW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura de Operación\u003c\/td\u003e\n\u003ctd\u003e-40°C a +90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacidad de Corriente\u003c\/td\u003e\n\u003ctd\u003e20A Continuos\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltaje Nominal\u003c\/td\u003e\n\u003ctd\u003e600V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibilidad de Microinversores\u003c\/td\u003e\n\u003ctd\u003eAPSystems DS3D, DS3-H, YC600B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificaciones\u003c\/td\u003e\n\u003ctd\u003eUL SOOW, NEC 690, UL 4703\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistencia UV\u003c\/td\u003e\n\u003ctd\u003eSí, certificado para intemperie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCódigo de Colores\u003c\/td\u003e\n\u003ctd\u003eNegro (Fase), Blanco (Neutro), Verde (Tierra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguración de Conexión\u003c\/td\u003e\n\u003ctd\u003eDaisy-Chain (Conexión en Cadena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensiones y Peso\u003c\/th\u003e\n\u003cth\u003eValor\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiámetro Exterior Aproximado\u003c\/td\u003e\n\u003ctd\u003e11.2 mm (0.44\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio de Curvatura Mínimo\u003c\/td\u003e\n\u003ctd\u003e8x diámetro exterior (89.6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePresentación\u003c\/td\u003e\n\u003ctd\u003eLongitudes estándar o a medida\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eContenido del Paquete\u003c\/h2\u003e\n\u003cdiv class=\"contenido-grid\"\u003e\n\u003cspan class=\"contenido-chip\"\u003e🔌 1x Cable Bus AC 3 Hilos 12 AWG APSystems\u003c\/span\u003e\u003cspan class=\"contenido-chip\"\u003e📄 Manual de Instalación\u003c\/span\u003e\u003cspan class=\"contenido-chip\"\u003e✅ Certificados de Cumplimiento UL\/NEC\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003eAplicaciones Recomendadas\u003c\/h2\u003e\n\u003cdiv class=\"apps-grid\"\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003e⚡ Sistemas Solares Residenciales\u003c\/strong\u003eInterconexión de microinversores APSystems DS3D, DS3-H o YC600B en instalaciones fotovoltaicas residenciales de 3-12 kW con arquitectura distribuida\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003e🏢 Instalaciones Comerciales\u003c\/strong\u003eCableado AC bus en sistemas solares comerciales con múltiples strings de microinversores en azoteas planas e inclinadas\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003e🏠 Techos con Sombreado\u003c\/strong\u003eSistemas donde cada panel requiere optimización individual por sombreado parcial de árboles, chimeneas o edificios adyacentes\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003e🔧 Reemplazo y Ampliación\u003c\/strong\u003eExtensión de sistemas solares APSystems existentes o reemplazo de cable bus deteriorado en instalaciones de 5+ años\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eProductos Complementarios\u003c\/h2\u003e\n\u003cdiv class=\"apps-grid\"\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003eMicroinversor APSystems DS3-D\u003c\/strong\u003eMicroinversor dual 1400W para 2 paneles solares de 330-550W, compatible con este cable bus AC\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003eMicroinversor APSystems DS3-H\u003c\/strong\u003eMicroinversor dual 1600W para 2 paneles de alta potencia 370-600W, requiere cable bus 12 AWG\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003eMicroinversor APSystems YC600B\u003c\/strong\u003eMicroinversor dual 600W para 2 paneles de 270-375W, usa mismo sistema de cable bus\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003eGateway de Comunicación APSystems ECU-C\u003c\/strong\u003eUnidad de monitoreo y comunicación para sistemas APSystems, centraliza datos de microinversores\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003eConector de Bloqueo Rápido AC APSystems\u003c\/strong\u003eConectores macho\/hembra de instalación rápida sin herramientas para cable bus 12 AWG\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003eCable Fotovoltaico 10 AWG\u003c\/strong\u003eCable solar DC para interconectar paneles con microinversores en lado de corriente directa\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003ePreguntas Frecuentes\u003c\/h2\u003e\n\u003cdetails class=\"faq-item\" open\u003e\u003csummary\u003e¿Cuántos microinversores APSystems puedo conectar en cadena con un ramal de cable 12 AWG?\u003c\/summary\u003e\u003cdiv class=\"faq-body\"\u003eEl número máximo de microinversores en cadena daisy-chain con cable 12 AWG depende de la longitud total del ramal y la caída de voltaje permitida (típicamente 3% según NEC 690.8). Para microinversores DS3-D\/DS3-H operando a 240V AC, se recomienda máximo 10-12 unidades en un ramal de hasta 60 metros. Para distancias mayores o más microinversores, considere calibre 10 AWG o divisiones de ramal. Siempre consulte las guías de diseño APSystems y códigos eléctricos locales.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"faq-item\" open\u003e\u003csummary\u003e¿Este cable es adecuado para instalación enterrada o en conduit subterráneo?\u003c\/summary\u003e\u003cdiv class=\"faq-body\"\u003eEl cable SOOW está certificado para uso en intemperie y exposición directa al sol, pero NO está listado como cable de enterramiento directo tipo UF o USE. Para instalaciones subterráneas, debe colocarse dentro de conduit PVC Schedule 40\/80 enterrado a profundidad según NEC 300.5 (típicamente 45-60 cm). Para tramos en azotea o fachada expuestos, el cable SOOW puede instalarse sin conduit si está correctamente sujetado y protegido contra daño mecánico. Verifique requisitos de AHJ (autoridad local) antes de la instalación.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"faq-item\" open\u003e\u003csummary\u003e¿Puedo usar este cable bus para interconectar microinversores de otras marcas como Enphase o Hoymiles?\u003c\/summary\u003e\u003cdiv class=\"faq-body\"\u003eNo se recomienda. Aunque el cable 12 AWG SOOW cumple especificaciones eléctricas generales, el sistema de conectores de bloqueo rápido APSystems es propietario y NO es compatible con sistemas de conexión de otras marcas como Enphase Q-Cable o cables troncales Hoymiles. Además, usar componentes no especificados por el fabricante puede invalidar garantías y certificaciones UL del sistema completo. Para sistemas multi-marca, utilice cable y conectores especificados por cada fabricante de microinversor en sus respectivos ramales.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"faq-item\" open\u003e\u003csummary\u003e¿Qué longitudes están disponibles y cómo determino cuánto cable necesito?\u003c\/summary\u003e\u003cdiv class=\"faq-body\"\u003eEl cable bus APSystems se ofrece en longitudes pre-cortadas estándar (típicamente rollos de 30m, 60m, 100m) y puede ordenarse a medida para proyectos específicos. Para calcular la longitud necesaria: (1) Dibuje layout del sistema en plano de techo, (2) Mida distancia entre microinversores en cadena daisy-chain (típicamente espaciados cada 1.5-3 metros según separación de paneles), (3) Agregue 20% adicional para curvas, subidas\/bajadas y conexión final al combiner box o desconectador AC, (4) Considere cable adicional para futuros mantenimientos. Software de diseño como APSystems Design Tool calcula automáticamente requerimientos de cable.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"faq-item\" open\u003e\u003csummary\u003e¿Necesito protección adicional contra sobrecorriente en el cable bus de microinversores?\u003c\/summary\u003e\u003cdiv class=\"faq-body\"\u003eSegún NEC 690.9, los circuitos de salida AC de microinversores deben estar protegidos contra sobrecorriente. Típicamente esto se logra mediante breaker dedicado de 20A en el panel eléctrico principal (para cable 12 AWG) dimensionado al 125% de la corriente máxima del ramal (suma de corrientes AC de todos los microinversores en cadena). El breaker protege el cable bus contra sobrecarga y cortocircuito. Para ramales largos con múltiples microinversores, verifique que la corriente total no exceda 16A continuos (80% de 20A) para cumplir NEC 210.20(A). No se requieren fusibles adicionales en cada microinversor ya que incluyen protecciones internas.\u003c\/div\u003e\u003c\/details\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"¿Cuántos microinversores APSystems puedo conectar en cadena con un ramal de cable 12 AWG?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"El número máximo de microinversores en cadena daisy-chain con cable 12 AWG depende de la longitud total del ramal y la caída de voltaje permitida (típicamente 3% según NEC 690.8). Para microinversores DS3-D\/DS3-H operando a 240V AC, se recomienda máximo 10-12 unidades en un ramal de hasta 60 metros. Para distancias mayores o más microinversores, considere calibre 10 AWG o divisiones de ramal. Siempre consulte las guías de diseño APSystems y códigos eléctricos locales.\"}},{\"@type\":\"Question\",\"name\":\"¿Este cable es adecuado para instalación enterrada o en conduit subterráneo?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"El cable SOOW está certificado para uso en intemperie y exposición directa al sol, pero NO está listado como cable de enterramiento directo tipo UF o USE. Para instalaciones subterráneas, debe colocarse dentro de conduit PVC Schedule 40\/80 enterrado a profundidad según NEC 300.5 (típicamente 45-60 cm). Para tramos en azotea o fachada expuestos, el cable SOOW puede instalarse sin conduit si está correctamente sujetado y protegido contra daño mecánico. Verifique requisitos de AHJ (autoridad local) antes de la instalación.\"}},{\"@type\":\"Question\",\"name\":\"¿Puedo usar este cable bus para interconectar microinversores de otras marcas como Enphase o Hoymiles?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No se recomienda. Aunque el cable 12 AWG SOOW cumple especificaciones eléctricas generales, el sistema de conectores de bloqueo rápido APSystems es propietario y NO es compatible con sistemas de conexión de otras marcas como Enphase Q-Cable o cables troncales Hoymiles. Además, usar componentes no especificados por el fabricante puede invalidar garantías y certificaciones UL del sistema completo. Para sistemas multi-marca, utilice cable y conectores especificados por cada fabricante de microinversor en sus respectivos ramales.\"}},{\"@type\":\"Question\",\"name\":\"¿Qué longitudes están disponibles y cómo determino cuánto cable necesito?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"El cable bus APSystems se ofrece en longitudes pre-cortadas estándar (típicamente rollos de 30m, 60m, 100m) y puede ordenarse a medida para proyectos específicos. Para calcular la longitud necesaria: (1) Dibuje layout del sistema en plano de techo, (2) Mida distancia entre microinversores en cadena daisy-chain (típicamente espaciados cada 1.5-3 metros según separación de paneles), (3) Agregue 20% adicional para curvas, subidas\/bajadas y conexión final al combiner box o desconectador AC, (4) Considere cable adicional para futuros mantenimientos. Software de diseño como APSystems Design Tool calcula automáticamente requerimientos de cable.\"}},{\"@type\":\"Question\",\"name\":\"¿Necesito protección adicional contra sobrecorriente en el cable bus de microinversores?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Según NEC 690.9, los circuitos de salida AC de microinversores deben estar protegidos contra sobrecorriente. Típicamente esto se logra mediante breaker dedicado de 20A en el panel eléctrico principal (para cable 12 AWG) dimensionado al 125% de la corriente máxima del ramal (suma de corrientes AC de todos los microinversores en cadena). El breaker protege el cable bus contra sobrecarga y cortocircuito. Para ramales largos con múltiples microinversores, verifique que la corriente total no exceda 16A continuos (80% de 20A) para cumplir NEC 210.20(A). No se requieren fusibles adicionales en cada microinversor ya que incluyen protecciones internas.\"}}]}\u003c\/script\u003e\n\u003c\/div\u003e","brand":"APSYSTEMS","offers":[{"title":"Default Title","offer_id":44415422365738,"sku":"APS-BusCable-DS3\/YC600-12AWG","price":400.99,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0550\/2117\/4826\/files\/silymx-12awg-3wire-ac-bus-cable-for-apsystems-microinverters-a1b2c3d4.jpg?v=1780441874","url":"https:\/\/sily.mx\/products\/bus-cable-3-wire-de-corriente-alterna-apsystems-12awg-para-ds3d-ds3-h-y-yc600b","provider":"SILYMX","version":"1.0","type":"link"}