{"product_id":"cable-de-fibra-optica-armado-6-hilos-multimodo-om4-50-125-loose-tube-250-µm-ofcr-riser-interior-exterior","title":"Cable Fibra Óptica OSP 6 Hilos Multimodo OM4 Armado OFCR Riser 250µm Panduit FOGRZ06Y","description":"\u003cstyle\u003e.mt-desc{color:#1a1a1a;max-width:860px;margin:0 auto;line-height:1.65}.mt-desc h1{font-size:26px;font-weight:800;margin-bottom:6px}.mt-desc .subtitulo{font-size:15px;color:#555;margin-bottom:24px}.mt-desc h2{font-size:19px;font-weight:700;border-left:4px solid #cc1f1f;padding-left:10px;margin:30px 0 12px}.mt-desc p{margin:0 0 14px;font-size:15px}.mt-desc ul{margin:0 0 14px 18px;padding:0}.mt-desc li{margin-bottom:7px;font-size:15px}.mt-desc table{width:100%;border-collapse:collapse;margin:12px 0 20px;font-size:14px}.mt-desc th{background:#f2f2f2;padding:10px 12px;text-align:left;font-weight:700;border-bottom:2px solid #ddd}.mt-desc td{padding:9px 12px;border-bottom:1px solid #eee}.mt-desc td:first-child{font-weight:600;width:42%}.mt-desc .faq-item{border:1px solid #e8e8e8;border-radius:8px;margin:10px 0;overflow:hidden}.mt-desc .faq-item summary{cursor:pointer;padding:13px 16px;font-weight:700;font-size:15px;list-style:none;background:#fafafa}.mt-desc .faq-item .faq-body{padding:12px 16px 14px;font-size:14px;border-top:1px solid #eee}.mt-desc .badge-row{display:flex;flex-wrap:wrap;gap:10px;margin:12px 0 20px}.mt-desc .badge{background:#f0f4ff;color:#1a3cc8;border:1px solid #c5d0f5;border-radius:20px;padding:5px 14px;font-size:13px;font-weight:600}.mt-desc .badge.green{background:#f0fff4;color:#1a7a3c;border-color:#b2dfca}.mt-desc .badge.red{background:#fff0f0;color:#b00020;border-color:#f5c5c5}.mt-desc .badge.gray{background:#f5f5f5;color:#444;border-color:#ddd}.mt-desc .badge.yellow{background:#fffbe6;color:#7a5c00;border-color:#f0d870}.mt-desc .apps-grid{display:grid;grid-template-columns:1fr 1fr;gap:10px;margin:12px 0}.mt-desc .app-card{background:#f8f8f8;border-radius:8px;padding:12px 14px;font-size:14px;border-left:3px solid #cc1f1f}.mt-desc .app-card strong{display:block;margin-bottom:4px}.mt-desc .contenido-grid{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0}.mt-desc .contenido-chip{background:#fff0f0;border:1px solid #f5c5c5;border-radius:6px;padding:6px 14px;font-size:14px;color:#b00020;font-weight:600}\u003c\/style\u003e\u003cdiv class=\"mt-desc\"\u003e\n\u003ch1\u003eCable de Fibra Óptica Armado 6 Hilos Multimodo OM4 50\/125 Loose Tube 250 µm OFCR Riser Interior-Exterior Panduit FOGRZ06Y\u003c\/h1\u003e\n\u003cp class=\"subtitulo\"\u003eModelo FOGRZ06Y — Marca Panduit\u003c\/p\u003e\n\u003cdiv class=\"badge-row\"\u003e\n\u003cspan class=\"badge yellow\"\u003eVenta por metro\u003c\/span\u003e\u003cspan class=\"badge green\"\u003e6 Hilos\u003c\/span\u003e\u003cspan class=\"badge\"\u003eMultimodo OM4 50\/125 µm\u003c\/span\u003e\u003cspan class=\"badge\"\u003eLoose Tube 250 µm\u003c\/span\u003e\u003cspan class=\"badge gray\"\u003eConstrucción Armada\u003c\/span\u003e\u003cspan class=\"badge\"\u003eOFCR Riser\u003c\/span\u003e\u003cspan class=\"badge\"\u003eInterior\/Exterior\u003c\/span\u003e\u003cspan class=\"badge\"\u003eTIA-598-C\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff4e5;border-left:4px solid #ff9500;border-radius:6px;padding:14px 16px;margin:16px 0;\"\u003e\n\u003cstrong style=\"color:#c26400;display:block;margin-bottom:6px;font-size:15px;\"\u003e⚠ Verificar precio y disponibilidad con ejecutivo\u003c\/strong\u003e\u003cspan style=\"color:#333;font-size:14px;line-height:1.6;\"\u003eEl precio mostrado es \u003cstrong\u003ereferencial por metro lineal\u003c\/strong\u003e. El costo por metro o pie lineal puede \u003cstrong\u003evariar\u003c\/strong\u003e segun proveedor, corte solicitado y disponibilidad (nuestros proveedores utilizan el mismo SKU para distintos cortes). Este cable se comercializa por \u003cstrong\u003ecorte a medida\u003c\/strong\u003e (metros o pies lineales) o en \u003cstrong\u003ebobinas estandar de 500m, 1000m, 2000m o 4000m\u003c\/strong\u003e. Contactanos antes de comprar para confirmar precio exacto y cortes disponibles.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp\u003eEl cable de fibra óptica Panduit FOGRZ06Y es un cable multimodo OM4 50\/125 µm con seis hilos en configuración loose tube de 250 µm, diseñado específicamente para instalaciones que demandan protección mecánica superior en trayectorias verticales y horizontales. Cumple con ISO\/IEC 11801:2002 OM3, ANSI\/TIA\/EIA-568-C.3, ANSI\/TIA-598-C y ANSI\/TIA-492 AAAC, además de Telcordia GR-409-CORE. La construcción armada permite el despliegue tanto en ambientes interiores como exteriores sin requerir conducto adicional, ofreciendo resistencia mecánica durante instalaciones en plenum vertical u horizontal.\u003c\/p\u003e\n\u003cp\u003eEl revestimiento OFCR (Optical Fiber Cable Riser) cumple las normativas de propagación de llama para instalaciones en eje vertical de edificios comerciales e industriales. La codificación de colores según estándar TIA-598-C facilita la identificación rápida de cada fibra durante trabajos de fusión y terminación en campo, mientras que las marcas de longitud cada 2 pies (0.61 metros) permiten mediciones precisas sin necesidad de equipamiento especializado. La fibra OM4 ofrece retrocompatibilidad con OM3, permitiendo migraciones graduales de red sin reemplazo total de infraestructura.\u003c\/p\u003e\n\u003cp\u003eEste cable de fibra óptica para tendido se comercializa con distribución nacional en México, disponible por corte a medida o en bobinas estándar de 500m, 1000m, 2000m o 4000m, con facturación CFDI y asesoría técnica especializada para proyectos de cableado estructurado.\u003c\/p\u003e\n\u003ch2\u003eBeneficios Principales\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFibra multimodo OM4 50\/125 µm con 6 hilos en loose tube de 250 µm para redes de alta velocidad hasta 10\/40\/100 Gigabit Ethernet.\u003c\/li\u003e\n\u003cli\u003eConstrucción armada que proporciona protección mecánica superior durante instalación y operación en ambientes interior-exterior.\u003c\/li\u003e\n\u003cli\u003eClasificación OFCR Riser que cumple normativas de propagación de llama para instalaciones verticales en edificios (plenums, risers, shafts).\u003c\/li\u003e\n\u003cli\u003eMarcas de longitud cada 2 pies (0.61 m) impresas en la chaqueta para medición precisa sin herramientas adicionales.\u003c\/li\u003e\n\u003cli\u003eCódigo de colores TIA-598-C que facilita identificación visual durante fusiones, empalmes y terminaciones en campo.\u003c\/li\u003e\n\u003cli\u003eRetrocompatibilidad con redes OM3 según ISO\/IEC 11801:2002, permitiendo integración con infraestructura existente.\u003c\/li\u003e\n\u003cli\u003eCertificaciones ANSI\/TIA\/EIA-568-C.3, ANSI\/TIA-598-C, ANSI\/TIA-492 AAAC y Telcordia GR-409-CORE para instalaciones críticas.\u003c\/li\u003e\n\u003cli\u003eDiseño loose tube de 250 µm que protege las fibras contra estrés mecánico y variaciones térmicas en tendido exterior.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEspecificaciones Tecnicas\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCaracterística\u003c\/th\u003e\n\u003cth\u003eEspecificación\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnidad de venta\u003c\/td\u003e\n\u003ctd\u003eMetro lineal \/ Pie lineal (verificar con ejecutivo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCortes disponibles\u003c\/td\u003e\n\u003ctd\u003eA medida o Bobinas estándar 500m, 1000m, 2000m, 4000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo de fibra óptica\u003c\/td\u003e\n\u003ctd\u003eMultimodo OM4 50\/125 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNúmero de hilos\u003c\/td\u003e\n\u003ctd\u003e6 hilos de fibra óptica\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModo de transmisión\u003c\/td\u003e\n\u003ctd\u003eMultimodo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevestimiento de fibra\u003c\/td\u003e\n\u003ctd\u003e125 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguración loose tube\u003c\/td\u003e\n\u003ctd\u003e250 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstrucción del cable\u003c\/td\u003e\n\u003ctd\u003eArmada (protección mecánica)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClasificación de fuego\u003c\/td\u003e\n\u003ctd\u003eOFCR (Riser) para instalaciones verticales\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAplicación\u003c\/td\u003e\n\u003ctd\u003eInterior\/Exterior (ISP\/OSP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarcas de longitud\u003c\/td\u003e\n\u003ctd\u003eCada 2 pies (0.61 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCódigo de colores\u003c\/td\u003e\n\u003ctd\u003eTIA-598-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRetrocompatibilidad\u003c\/td\u003e\n\u003ctd\u003eOM3 según ISO\/IEC 11801:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificaciones\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801:2002 OM3, ANSI\/TIA\/EIA-568-C.3, ANSI\/TIA-598-C, ANSI\/TIA-492 AAAC, Telcordia GR-409-CORE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarca\u003c\/td\u003e\n\u003ctd\u003ePanduit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelo\/SKU\u003c\/td\u003e\n\u003ctd\u003eFOGRZ06Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAplicaciones Recomendadas\u003c\/h2\u003e\n\u003cdiv class=\"apps-grid\"\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003e🏢 Backbone vertical en edificios corporativos\u003c\/strong\u003eInstalación en risers, shafts y plenums verticales con cumplimiento OFCR para propagación de llama controlada.\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003e🏭 Redes industriales de alta velocidad\u003c\/strong\u003eDespliegue en plantas industriales que requieren fibra OM4 para 10\/40\/100 Gigabit Ethernet con protección armada.\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003e🏫 Campus universitarios y hospitales\u003c\/strong\u003eTendido interior-exterior entre edificios con un solo tipo de cable armado, sin necesidad de conducto adicional.\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003e📡 Centros de datos y telecomunicaciones\u003c\/strong\u003eInterconexión de racks, distribuidores y equipos activos en infraestructura crítica con certificación Telcordia GR-409-CORE.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003ePreguntas Frecuentes\u003c\/h2\u003e\n\u003cdetails class=\"faq-item\" open\u003e\u003csummary\u003e¿Cómo se vende este cable de fibra óptica Panduit FOGRZ06Y?\u003c\/summary\u003e\u003cdiv class=\"faq-body\"\u003eEste cable se vende por metro lineal o pie lineal, con precio variable según proveedor y corte solicitado. Está disponible en cortes a medida o en bobinas estándar de 500m, 1000m, 2000m o 4000m. Debido a que los proveedores utilizan el mismo SKU para distintos cortes y la disponibilidad puede variar, es necesario verificar precio exacto y disponibilidad con un ejecutivo de ventas antes de realizar la compra.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"faq-item\" open\u003e\u003csummary\u003e¿Qué distancia máxima soporta la fibra OM4 de este cable?\u003c\/summary\u003e\u003cdiv class=\"faq-body\"\u003eLa fibra multimodo OM4 50\/125 µm del cable Panduit FOGRZ06Y soporta hasta 550 metros a 10 Gbps (10GBASE-SR), 150 metros a 40 Gbps y 100 metros a 100 Gbps según estándares IEEE. Es retrocompatible con redes OM3, lo que permite integración con infraestructura existente y migraciones graduales sin reemplazo completo de cableado.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"faq-item\" open\u003e\u003csummary\u003e¿Puedo instalar este cable tanto en interior como en exterior?\u003c\/summary\u003e\u003cdiv class=\"faq-body\"\u003eSí, el cable FOGRZ06Y tiene construcción armada que permite instalación en ambientes interiores y exteriores sin necesidad de conducto adicional. La armadura proporciona protección mecánica contra impactos, roedores y estrés durante el tendido. Sin embargo, la clasificación OFCR (Riser) está específicamente diseñada para instalaciones verticales en edificios, cumpliendo normativas de propagación de llama.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"faq-item\" open\u003e\u003csummary\u003e¿Qué significa la configuración loose tube de 250 µm?\u003c\/summary\u003e\u003cdiv class=\"faq-body\"\u003eLoose tube (tubo holgado) de 250 µm es una construcción donde cada fibra de 125 µm de revestimiento está contenida dentro de un tubo protector de 250 µm, permitiendo movimiento libre de la fibra dentro del tubo. Esta configuración protege las fibras contra estrés mecánico, variaciones térmicas y expansión-contracción del cable, siendo ideal para tendidos exteriores y verticales de larga longitud.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"faq-item\" open\u003e\u003csummary\u003e¿Qué normativas cumple este cable de fibra óptica?\u003c\/summary\u003e\u003cdiv class=\"faq-body\"\u003eEl cable Panduit FOGRZ06Y cumple con ISO\/IEC 11801:2002 OM3, ANSI\/TIA\/EIA-568-C.3 para cableado de telecomunicaciones, ANSI\/TIA-598-C para código de colores de fibra óptica, ANSI\/TIA-492 AAAC para especificaciones de fibra multimodo, y Telcordia GR-409-CORE para cables de fibra óptica de planta interna. La clasificación OFCR cumple normativas NEC para propagación de llama en risers verticales.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"faq-item\" open\u003e\u003csummary\u003e¿Cuál es la función de las marcas de longitud cada 2 pies?\u003c\/summary\u003e\u003cdiv class=\"faq-body\"\u003eLas marcas de longitud impresas cada 2 pies (0.61 metros) en la chaqueta del cable FOGRZ06Y permiten medición precisa de la longitud tendida sin necesidad de cinta métrica o equipamiento especializado. Esto facilita el cálculo de longitudes durante instalación, verificación de inventario, planeación de fusiones y documentación de infraestructura de cableado estructurado en campo.\u003c\/div\u003e\u003c\/details\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"¿Cómo se vende este cable de fibra óptica Panduit FOGRZ06Y?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Este cable se vende por metro lineal o pie lineal, con precio variable según proveedor y corte solicitado. Está disponible en cortes a medida o en bobinas estándar de 500m, 1000m, 2000m o 4000m. Debido a que los proveedores utilizan el mismo SKU para distintos cortes y la disponibilidad puede variar, es necesario verificar precio exacto y disponibilidad con un ejecutivo de ventas antes de realizar la compra.\"}},{\"@type\":\"Question\",\"name\":\"¿Qué distancia máxima soporta la fibra OM4 de este cable?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"La fibra multimodo OM4 50\/125 µm del cable Panduit FOGRZ06Y soporta hasta 550 metros a 10 Gbps (10GBASE-SR), 150 metros a 40 Gbps y 100 metros a 100 Gbps según estándares IEEE. Es retrocompatible con redes OM3, lo que permite integración con infraestructura existente y migraciones graduales sin reemplazo completo de cableado.\"}},{\"@type\":\"Question\",\"name\":\"¿Puedo instalar este cable tanto en interior como en exterior?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Sí, el cable FOGRZ06Y tiene construcción armada que permite instalación en ambientes interiores y exteriores sin necesidad de conducto adicional. La armadura proporciona protección mecánica contra impactos, roedores y estrés durante el tendido. Sin embargo, la clasificación OFCR (Riser) está específicamente diseñada para instalaciones verticales en edificios, cumpliendo normativas de propagación de llama.\"}},{\"@type\":\"Question\",\"name\":\"¿Qué significa la configuración loose tube de 250 µm?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Loose tube (tubo holgado) de 250 µm es una construcción donde cada fibra de 125 µm de revestimiento está contenida dentro de un tubo protector de 250 µm, permitiendo movimiento libre de la fibra dentro del tubo. Esta configuración protege las fibras contra estrés mecánico, variaciones térmicas y expansión-contracción del cable, siendo ideal para tendidos exteriores y verticales de larga longitud.\"}},{\"@type\":\"Question\",\"name\":\"¿Qué normativas cumple este cable de fibra óptica?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"El cable Panduit FOGRZ06Y cumple con ISO\/IEC 11801:2002 OM3, ANSI\/TIA\/EIA-568-C.3 para cableado de telecomunicaciones, ANSI\/TIA-598-C para código de colores de fibra óptica, ANSI\/TIA-492 AAAC para especificaciones de fibra multimodo, y Telcordia GR-409-CORE para cables de fibra óptica de planta interna. La clasificación OFCR cumple normativas NEC para propagación de llama en risers verticales.\"}},{\"@type\":\"Question\",\"name\":\"¿Cuál es la función de las marcas de longitud cada 2 pies?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Las marcas de longitud impresas cada 2 pies (0.61 metros) en la chaqueta del cable FOGRZ06Y permiten medición precisa de la longitud tendida sin necesidad de cinta métrica o equipamiento especializado. Esto facilita el cálculo de longitudes durante instalación, verificación de inventario, planeación de fusiones y documentación de infraestructura de cableado estructurado en campo.\"}}]}\u003c\/script\u003e\n\u003c\/div\u003e","brand":"PANDUIT","offers":[{"title":"Default Title","offer_id":44818750275626,"sku":"FOGRZ06Y","price":25.91,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0550\/2117\/4826\/files\/portada_0S1000_c0e3b8e9-7fc2-4394-95f1-8f8dd2a20ab0.png?v=1789064085","url":"https:\/\/sily.mx\/products\/cable-de-fibra-optica-armado-6-hilos-multimodo-om4-50-125-loose-tube-250-%c2%b5m-ofcr-riser-interior-exterior","provider":"SILYMX","version":"1.0","type":"link"}