{"product_id":"datamanager-m-para-inversores-sma","title":"Datamanager M Monitoreo Inversores Solares RS485 Ethernet SMA EDMM-US-20","description":"\u003cdiv class=\"mt-desc\"\u003e\n\u003cstyle\u003e.mt-desc{color:#1a1a1a;max-width:860px;margin:0 auto;line-height:1.65}.mt-desc h1{font-size:26px;font-weight:800;margin-bottom:6px}.mt-desc h2{font-size:19px;font-weight:700;border-left:4px solid #cc1f1f;padding-left:10px;margin:30px 0 12px}.mt-desc p{margin:0 0 14px;font-size:15px}.mt-desc ul{margin:0 0 14px 18px;padding:0}.mt-desc li{margin-bottom:7px;font-size:15px}.mt-desc table{width:100%;border-collapse:collapse;margin:12px 0 20px;font-size:14px}.mt-desc th{background:#f2f2f2;padding:10px 12px;text-align:left;font-weight:700;border-bottom:2px solid #ddd}.mt-desc td{padding:9px 12px;border-bottom:1px solid #eee}.mt-desc td:first-child{font-weight:600;width:42%}.mt-desc .faq-item{border:1px solid #e8e8e8;border-radius:8px;margin:10px 0;overflow:hidden}.mt-desc .faq-item summary{cursor:pointer;padding:13px 16px;font-weight:700;font-size:15px;list-style:none;background:#fafafa}.mt-desc .faq-item .faq-body{padding:12px 16px 14px;font-size:14px;border-top:1px solid #eee}.mt-desc .badge-row{display:flex;flex-wrap:wrap;gap:10px;margin:12px 0 20px}.mt-desc .badge{background:#f0f4ff;color:#1a3cc8;border:1px solid #c5d0f5;border-radius:20px;padding:5px 14px;font-size:13px;font-weight:600}.mt-desc .badge.green{background:#f0fff4;color:#1a7a3c;border-color:#b2dfca}.mt-desc .badge.red{background:#fff0f0;color:#b00020;border-color:#f5c5c5}.mt-desc .badge.gray{background:#f5f5f5;color:#444;border-color:#ddd}.mt-desc .badge.yellow{background:#fffbe6;color:#7a5c00;border-color:#f0d870}.mt-desc .apps-grid{display:grid;grid-template-columns:1fr 1fr;gap:10px;margin:12px 0}.mt-desc .app-card{background:#f8f8f8;border-radius:8px;padding:12px 14px;font-size:14px;border-left:3px solid #cc1f1f}.mt-desc .app-card strong{display:block;margin-bottom:4px}.mt-desc .contenido-grid{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0}.mt-desc .contenido-chip{background:#fff0f0;border:1px solid #f5c5c5;border-radius:6px;padding:6px 14px;font-size:14px;color:#b00020;font-weight:600}.mt-desc .subtitulo{font-size:15px;color:#555;margin-bottom:24px}\u003c\/style\u003e\n\u003ch1\u003eDatamanager M para inversores SMA\u003c\/h1\u003e\n\u003cp class=\"subtitulo\"\u003eModelo EDMM-US-20 | Marca SMA\u003c\/p\u003e\n\u003cdiv class=\"badge-row\"\u003e\n\u003cspan class=\"badge green\"\u003eMonitoreo Avanzado\u003c\/span\u003e\u003cspan class=\"badge\"\u003eConectividad Ethernet\u003c\/span\u003e\u003cspan class=\"badge yellow\"\u003eCompatible SMA\u003c\/span\u003e\u003cspan class=\"badge\"\u003eGestión Remota\u003c\/span\u003e\u003cspan class=\"badge gray\"\u003eComunicación RS485\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp\u003eEl Datamanager M de SMA es un dispositivo de monitoreo y comunicación profesional diseñado para la gestión centralizada de instalaciones fotovoltaicas con inversores SMA. Opera mediante protocolo Modbus RTU a 9600 baudios sobre RS485, permitiendo la supervisión en tiempo real de hasta 50 inversores simultáneamente a través de conexión Ethernet 10\/100 Mbps con puerto RJ45.\u003c\/p\u003e\n\u003cp\u003eEste módulo de gestión inteligente permite la visualización completa de datos de producción solar, análisis de rendimiento energético y diagnóstico remoto de plantas fotovoltaicas. Ideal para instalaciones comerciales e industriales que requieren monitoreo profesional y control eficiente de sus sistemas de generación solar.\u003c\/p\u003e\n\u003ch2\u003eBeneficios Principales\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoreo centralizado de hasta 50 inversores SMA en una sola plataforma de gestión\u003c\/li\u003e\n\u003cli\u003eComunicación bidireccional RS485 con protocolo Modbus RTU para integración con sistemas SCADA\u003c\/li\u003e\n\u003cli\u003eConectividad Ethernet RJ45 10\/100 Mbps para acceso remoto y visualización web\u003c\/li\u003e\n\u003cli\u003eAlmacenamiento interno de datos históricos de producción y eventos del sistema\u003c\/li\u003e\n\u003cli\u003eDiagnóstico automático de fallas y alertas en tiempo real para mantenimiento preventivo\u003c\/li\u003e\n\u003cli\u003eInterfaz web integrada para configuración y visualización sin software adicional\u003c\/li\u003e\n\u003cli\u003eCompatible con Sunny Portal y otras plataformas de monitoreo profesional SMA\u003c\/li\u003e\n\u003cli\u003eActualización de firmware remota para mejoras continuas del sistema\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEspecificaciones Técnicas\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCaracterística\u003c\/th\u003e\n\u003cth\u003eEspecificación\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelo\u003c\/td\u003e\n\u003ctd\u003eEDMM-US-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFabricante\u003c\/td\u003e\n\u003ctd\u003eSMA Solar Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo de Dispositivo\u003c\/td\u003e\n\u003ctd\u003eData Manager \/ Monitor de Comunicación\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePuerto Ethernet\u003c\/td\u003e\n\u003ctd\u003eRJ45 10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComunicación Inversores\u003c\/td\u003e\n\u003ctd\u003eRS485 Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocidad Comunicación\u003c\/td\u003e\n\u003ctd\u003e9600 baudios\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacidad Monitoreo\u003c\/td\u003e\n\u003ctd\u003eHasta 50 inversores SMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocolos Soportados\u003c\/td\u003e\n\u003ctd\u003eModbus RTU, TCP\/IP, HTTP, HTTPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaz Usuario\u003c\/td\u003e\n\u003ctd\u003eWeb browser integrado\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlmacenamiento Datos\u003c\/td\u003e\n\u003ctd\u003eMemoria interna\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlimentación\u003c\/td\u003e\n\u003ctd\u003e12-24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura Operación\u003c\/td\u003e\n\u003ctd\u003e-25°C a +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrado Protección\u003c\/td\u003e\n\u003ctd\u003eIP20 (uso interior)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMontaje\u003c\/td\u003e\n\u003ctd\u003eRiel DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibilidad\u003c\/td\u003e\n\u003ctd\u003eInversores SMA Sunny Boy, Sunny Tripower, Sunny Island\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eContenido del Paquete\u003c\/h2\u003e\n\u003cdiv class=\"contenido-grid\"\u003e\n\u003cspan class=\"contenido-chip\"\u003e📦 1x Datamanager M SMA EDMM-US-20\u003c\/span\u003e\u003cspan class=\"contenido-chip\"\u003e📘 Manual de instalación y configuración\u003c\/span\u003e\u003cspan class=\"contenido-chip\"\u003e🔧 Clip de montaje riel DIN\u003c\/span\u003e\u003cspan class=\"contenido-chip\"\u003e📄 Guía rápida de inicio\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003eAplicaciones Recomendadas\u003c\/h2\u003e\n\u003cdiv class=\"apps-grid\"\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003e🏭 Plantas Solares Comerciales\u003c\/strong\u003eMonitoreo centralizado de múltiples inversores en instalaciones de mediana y gran escala\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003e🏢 Edificios Corporativos\u003c\/strong\u003eSupervisión de sistemas fotovoltaicos en techos industriales y comerciales\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003e⚡ Granjas Solares\u003c\/strong\u003eGestión profesional de parques fotovoltaicos con análisis de producción energética\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003e🔌 Integración SCADA\u003c\/strong\u003eConexión con sistemas de automatización y control industrial mediante Modbus\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003e📊 Análisis de Rendimiento\u003c\/strong\u003eEvaluación de eficiencia y optimización de plantas solares existentes\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003cstrong\u003e🛠️ Mantenimiento Predictivo\u003c\/strong\u003eDiagnóstico remoto y alertas tempranas de fallas en inversores\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003ePreguntas Frecuentes\u003c\/h2\u003e\n\u003cdetails class=\"faq-item\" open\u003e\u003csummary\u003e¿Cuántos inversores SMA puedo monitorear con el Datamanager M?\u003c\/summary\u003e\u003cdiv class=\"faq-body\"\u003eEl Datamanager M puede gestionar hasta 50 inversores SMA simultáneamente mediante comunicación RS485 con protocolo Modbus RTU, permitiendo monitoreo centralizado de instalaciones solares de mediana y gran escala.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"faq-item\" open\u003e\u003csummary\u003e¿Es compatible con todos los modelos de inversores SMA?\u003c\/summary\u003e\u003cdiv class=\"faq-body\"\u003eSí, el Datamanager M es compatible con las principales líneas de inversores SMA incluyendo Sunny Boy, Sunny Tripower, Sunny Island y otros modelos que soporten comunicación RS485 Modbus. Verifique la compatibilidad específica de su modelo en la documentación técnica.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"faq-item\" open\u003e\u003csummary\u003e¿Necesito software adicional para visualizar los datos?\u003c\/summary\u003e\u003cdiv class=\"faq-body\"\u003eNo, el Datamanager M incluye una interfaz web integrada accesible mediante cualquier navegador web a través de la red Ethernet. Adicionalmente es compatible con Sunny Portal y otras plataformas de monitoreo profesional de SMA para análisis avanzados.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"faq-item\" open\u003e\u003csummary\u003e¿Cómo se conecta el Datamanager M a los inversores?\u003c\/summary\u003e\u003cdiv class=\"faq-body\"\u003eLa conexión se realiza mediante bus RS485 utilizando protocolo Modbus RTU a 9600 baudios. Los inversores se conectan en topología daisy-chain (serie) al puerto RS485 del Datamanager, y este se conecta a la red local mediante cable Ethernet RJ45.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"faq-item\" open\u003e\u003csummary\u003e¿Requiere conexión a internet para funcionar?\u003c\/summary\u003e\u003cdiv class=\"faq-body\"\u003eNo es obligatorio. El Datamanager M funciona en red local (LAN) sin conexión a internet, permitiendo monitoreo interno. Sin embargo, la conexión a internet es necesaria si desea acceso remoto externo o integración con plataformas cloud como Sunny Portal.\u003c\/div\u003e\u003c\/details\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"¿Cuántos inversores SMA puedo monitorear con el Datamanager M?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"El Datamanager M puede gestionar hasta 50 inversores SMA simultáneamente mediante comunicación RS485 con protocolo Modbus RTU, permitiendo monitoreo centralizado de instalaciones solares de mediana y gran escala.\"}},{\"@type\":\"Question\",\"name\":\"¿Es compatible con todos los modelos de inversores SMA?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Sí, el Datamanager M es compatible con las principales líneas de inversores SMA incluyendo Sunny Boy, Sunny Tripower, Sunny Island y otros modelos que soporten comunicación RS485 Modbus. Verifique la compatibilidad específica de su modelo en la documentación técnica.\"}},{\"@type\":\"Question\",\"name\":\"¿Necesito software adicional para visualizar los datos?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No, el Datamanager M incluye una interfaz web integrada accesible mediante cualquier navegador web a través de la red Ethernet. Adicionalmente es compatible con Sunny Portal y otras plataformas de monitoreo profesional de SMA para análisis avanzados.\"}},{\"@type\":\"Question\",\"name\":\"¿Cómo se conecta el Datamanager M a los inversores?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"La conexión se realiza mediante bus RS485 utilizando protocolo Modbus RTU a 9600 baudios. Los inversores se conectan en topología daisy-chain (serie) al puerto RS485 del Datamanager, y este se conecta a la red local mediante cable Ethernet RJ45.\"}},{\"@type\":\"Question\",\"name\":\"¿Requiere conexión a internet para funcionar?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No es obligatorio. El Datamanager M funciona en red local (LAN) sin conexión a internet, permitiendo monitoreo interno. Sin embargo, la conexión a internet es necesaria si desea acceso remoto externo o integración con plataformas cloud como Sunny Portal.\"}}]}\u003c\/script\u003e\n\u003c\/div\u003e","brand":"SMA","offers":[{"title":"Default Title","offer_id":44370573361194,"sku":"EDMM-US-20","price":34965.99,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0550\/2117\/4826\/files\/INVSMA1S6.png?v=1778892574","url":"https:\/\/sily.mx\/products\/datamanager-m-para-inversores-sma","provider":"SILYMX","version":"1.0","type":"link"}